Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathREADME.Rmd
153 lines (119 loc) · 8.21 KB
/
README.Rmd
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
---
title: "Thermimage: Calculation Checks"
output: github_document
---
```{r setup, include=FALSE}
knitr::opts_chunk$set(echo = TRUE)
```
### Check Thermimage calculations against FLIR Researcher Max output
The purpose of this script is to compare Thermimage's raw2temp() conversion calculations in the
Thermimage package against the standard values generated from numerous FLIR software programs
### Load in thermal image
```{r}
library(Thermimage)
thermal.palette<-"rainbow1234pal" # can choose form "flir","ironbow", "rainbow1234pal"
f<-"IguanaImageData/IguanaImage.JPG"
img<-readflirJPG(f, exiftoolpath="installed")
dim(img)
plotTherm(img, h=480, w=640, thermal.palette=rainbow1234pal, minrangeset=min(img), maxrangeset=max(img), trans="rotate270.matrix")
```
The plot above is simply the raw binary radiance values imported. The scale should be in raw units
where max possible = 2^16=65535 corresponding to the data storage method from FLIR jpgs)
We will calculate temperature below and compare to FLIR calculations, after extracting the calibration constants from the original flir jpg:
```{r}
f<-"IguanaImageData/IguanaImage.JPG"
plancks<-flirsettings(f, exiftoolpath="installed", camvals="-*Planck*")
unlist(plancks$Info)
```
### Import Raw Thermal Image Data
I took the thermal image above and loaded it into FLIR's Research R&D and FLIR's ExaminIR software. Some FLIR programs allow you to export the raw binary data (FLIR R&D Software, ExaminIR), so I exported both to .csv files, and load both files into r1 and r2 (i.e., raw values 1, real values 2):
```{r}
r1<-as.matrix(read.csv("IguanaImageData/IguanaRawR&D.csv", header=FALSE))
r2<-as.matrix(read.csv("IguanaImageData/IguanaRawExaminIR.csv", header=FALSE))
r1[1:5, 1:5] # show a 5x5 array of pixel values from r1
r2[1:5, 1:5] # show a 5x5 array of pixel values from r2 - looks the same as above
mean(r1-r2) # it is the same as above!
```
Since the mean value of if mean = 0 then both software outputs are using the same raw data. That's expected. However, FLIR is continually creating new software and often with very little difference in practical functionality to the researcher, but at great expense to a research budget, so it behoves to ask. Since there is little open disclosure of calculations between these software packages, does it matter which software to use in terms of temperature estimates?
### Do all FLIR Programs Perform the Same Calculations?
Below, I load in 3 files that represent the same image set to realistic emissivity and environmental
values, calculated within each program (Thermacam Researcher Pro v2.9, ExaminIR, and Flir Research R&D Max), and compare mean values (across all 307200 pixels):
```{r}
trealThermcam<-as.matrix(read.csv("IguanaImageData/IguanaActualTemperatureE0.96Temps20Thermcam.csv", header=FALSE))
# trealThermacam = the real temperature calculated from Thermacam Researcher Pro.
trealExamIR<-as.matrix(read.csv("IguanaImageData/IguanaActualTemperatureE0.96Temps20ExaminIR.csv", header=FALSE))
trealRD<-as.matrix(read.csv("IguanaImageData/IguanaActualTemperatureE0.96Temps20R&D.csv", header=FALSE, sep=";"))
mean(trealThermcam-trealExamIR) # -0.0786 oC difference
mean(trealThermcam-trealRD) # -0.1396 oC difference
mean(trealExamIR-trealRD) # -0.0609 oC difference
hist(trealThermcam-trealRD)
```
So 3 programs by FLIR that open the same image and have camera settings set to the same values, lead to to estimated temperatures that differ by 0.07 to 0.13 degrees C! The largest difference of -0.14 is between Thermacam Researcher Pro vs Research R&D Max. Some differences are as much as -0.25 degrees C. Presumably the algorithm has changed with the more recent software (R&D Max)?
But no explanation is provided for this, and this is the challenge of working with proprietary, non open source software. But these differences are fairly small, so perhaps we can ignore them. It does suggest caution, however in assuming all software is operating on the same principles.
### Change the Export Settings from FLIR Software
Here, the same image (IguanaImage.jpg) was analysed in Thermacam Researcher Pro but the settings changed on purpose and the temperature data exported to csv files. Below I added a less transmissive window, or I heated the window up, or I used a lower emissivity for the object (but kept the window transmittance = 1)
```{r}
tt0.9<-as.matrix(read.csv("IguanaImageData/Iguana_T0.9.csv", header=FALSE)) # transmission window = 0.9
tt0.7<-as.matrix(read.csv("IguanaImageData/Iguana_T0.7.csv", header=FALSE)) # transmission window = 0.7
trt40<-as.matrix(read.csv("IguanaImageData/Iguana_RT40.csv", header=FALSE)) # transmission window = 1, but the window temperature was set to 40C
te0.9<-as.matrix(read.csv("IguanaImageData/Iguana_E0.9.csv", header=FALSE)) # Emissivity = 0.9
```
clearly, changing parameters will distort estimates of temperature, but this is to be expected:
```{r}
mean(tt0.9-trealThermcam) # 1.549 oC
mean(tt0.7-trealThermcam) # 5.527 oC
mean(trt40-trealThermcam) # -0.95 oC
mean(te0.9-trealThermcam) # 0.88 oC
```
All of which drives home the point of setting parameters properly to ensure accurate results.
Recall the calibration parameters, they will be used in the calculations below:
```{r}
unlist(flirsettings("IguanaImageData/IguanaImage.jpg", camvals="-*Planck*")$Info)
```
### Compare Thermimage raw2temp() calculations to FLIR Software
Create 5 potential calculations of the IguanaImage.jpg data by changing key parameters used in the estimation of temperature:
```{r}
trealc<-raw2temp(r1, E=0.96, OD=1, RTemp=20, ATemp=20, IRT=1, RH=50,PR1 = 21106.77, PB = 1501, PF = 1, PO = -7340, PR2 = 0.012545258)
tt0.9c<-raw2temp(r1, E=0.96, OD=1, RTemp=20, ATemp=20, IRT=0.9, RH=50, PR1 = 21106.77, PB = 1501, PF = 1, PO = -7340, PR2 = 0.012545258)
tt0.7c<-raw2temp(r1, E=0.96, OD=1, RTemp=20, ATemp=20, IRT=0.7, RH=50, PR1 = 21106.77, PB = 1501, PF = 1, PO = -7340, PR2 = 0.012545258)
trt40c<-raw2temp(r1, E=0.96, OD=1, RTemp=40, ATemp=40, IRWTemp=40, IRT=1, RH=50, PR1 = 21106.77, PB = 1501, PF = 1, PO = -7340, PR2 = 0.012545258)
te0.9c<-raw2temp(r1, E=0.9, OD=1, RTemp=20, ATemp=20, IRT=1, RH=50,PR1 = 21106.77, PB = 1501, PF = 1, PO = -7340, PR2 = 0.012545258)
```
Compare Thermimage calculated values to the same settings as exported from Thermacam Researcher Pro:
```{r}
x<-trealc-trealThermcam
mean(x) # 0.033oC
sd(x)
hist(x, main="raw2temp calculation vs. Thermacam Pro")
x<-tt0.9c-tt0.9
mean(x) # -0.0497 oC
sd(x)
hist(x, main="raw2temp calculation vs. Thermacam Pro")
x<-tt0.7c-tt0.7
mean(x) # 0.044 oC
sd(x)
hist(x, main="raw2temp calculation vs. Thermacam Pro")
x<-trt40c-trt40
mean(x) # -0.028 oC
sd(x)
hist(x, main="raw2temp calculation vs. Thermacam Pro")
x<-te0.9c-te0.9
mean(x) # 0.035 oC
sd(x)
hist(x, main="raw2temp calculation vs. Thermacam Pro")
```
For all the above, the difference between Thermimage calculated values and Thermacam Researcher Pro exported values is ~0.03 to 0.04 oC which happens to be the resolution of the thermal camera used (Model SC660).
Therefore, it appears that calculations in raw2temp() are working as intended.
### Finally a plot of the image used to make these comparisons:
```{r}
plotTherm(tt0.9, h=480, w=640, minrangeset=20, maxrangeset=46, trans="rotate270.matrix", main="Temperatures from Thermacam Researcher Pro", thermal.palette=rainbow1234pal)
plotTherm(tt0.9c, h=480, w=640, minrangeset=20, maxrangeset=46, trans="rotate270.matrix", main="Temperatures from Thermimage's raw2temp function", thermal.palette=rainbow1234pal)
plotTherm(tt0.9-tt0.9c,h=480, w=640, minrangeset=-0.08, maxrangeset=0.08, trans="rotate270.matrix", main="Difference between raw2temp minus Thermacam Researcher Pro", thermal.palette=rainbow1234pal)
```
### References
Holst, G. C. (2000). Common sense approach to thermal imaging. Bellingham, Wash & Winter Park, Fla.: SPIE Optical Engineering Press; JCD Publishing.
Minkina, W. and Dudzik, S. (2009). Infrared thermography errors and uncertainties, pp. xix, 192 p. Chichester, West Sussex, U.K. ; Hoboken, NJ: J. Wiley.
Tattersall, G. J. (2016). Infrared thermography: A non-invasive window into thermal physiology. Comp Biochem Physiol A Mol Integr Physiol 202, 78-98.
### Online Resources
EEVBlog:
* raw to temperature conversion: http://u88.n24.queensu.ca/exiftool/forum/index.php?topic=4898.135